Drill Master 94436 Manual de usuario

Busca en linea o descarga Manual de usuario para Taladros Eléctricos Drill Master 94436. Dual Abutment Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 2

PROSTHESIS MANUALTypes of Abutment 11Prosthetic Procedure 1 12Abutment Level- Solid / Dual Abutment 13Abutment Level- SCA Abutment 16Prosthetic Proc

Pagina 3 - SURGICAL MANUAL

SimpleLine ll Surgical / Prosthesis Manual11Types of AbutmentAbutment LevelOne-PieceCylinderTwo-PiecesFixture LevelOctaScrew AbutmentDual Milling Abut

Pagina 4 - Surgical Drill Sequence

SimpleLine ll Surgical / Prosthesis Manual12Cemented RestorationProsthetic Procedure 1Impression Technique and Restoration SelectionSolid / Dual / SCA

Pagina 5 - Fixture Installation

SimpleLine ll Surgical / Prosthesis Manual13Abutment Level-Solid / Dual AbutmentClinical ProcedureHealing Abutment Solid Abutment orDual AbutmentAbutm

Pagina 6 - Fixture Connection

Abutment Level-Solid / Dual AbutmentSimpleLine ll Surgical / Prosthesis Manual14Laboratory ProcedureLab Analog Connection Cylinder Crown Wax-upFinal R

Pagina 7

SimpleLine ll Surgical / Prosthesis Manual15Abutment Level-Solid / Dual Abutment[Multiple Units]Shave off the extended margin by usingthe rubber wheel

Pagina 8 - Surgical Kit Maintenance

Abutment Level-SCA AbutmentSimpleLine ll Surgical / Prosthesis Manual16[Multiple Units]Clinical ProcedureFixture installation. Choose SCA abutment (Oc

Pagina 9 - Warnings

SimpleLine ll Surgical / Prosthesis Manual17Abutment Level-SCA Abutment[Multiple Units]Laboratory ProcedureLab Analog Connection Cylinder Crown Wax-up

Pagina 10 - PROSTHESIS MANUAL

SimpleLine ll Surgical / Prosthesis ManualAbutment Level- SCA Abutment18[Multiple Units]Shave off the extended margin by usingthe rubber wheel.Metal f

Pagina 11 - Types of Abutment

SimpleLine ll Surgical / Prosthesis Manual19Prosthetic Procedure 2Dual / SCA / Dual Milling / Angled / Direct-Casting /Metal-Casting / Temporary Abutm

Pagina 13 - Abutment Level

Fixture Level[Pick-up Type]-Dual AbutmentSimpleLine ll Surgical / Prosthesis Manual20[Multiple Units]Clinical ProcedureHealing Abutment Impression Cop

Pagina 14

SimpleLine ll Surgical / Prosthesis Manual21Fixture Level[Pick-up Type]-Dual Abutment[Multiple Units]Laboratory ProcedureLab Analog Connection Assembl

Pagina 15

Fixture Level[Pick-up Type]-Dual AbutmentSimpleLine ll Surgical / Prosthesis Manual22[Multiple Units]Final prosthesis. Use positioning jig to transfer

Pagina 16

SimpleLine ll Surgical / Prosthesis Manual23Fixture Level[Transfer Type]-Dual Abutment[Multiple Units]Clinical ProcedureHealing Abutment Impression Co

Pagina 17

Fixture Level[Transfer Type]-Dual AbutmentSimpleLine ll Surgical / Prosthesis Manual24Laboratory ProcedureLab Analog Connection Assemble theDual Abutm

Pagina 18

SimpleLine ll Surgical / Prosthesis Manual25Fixture Level[Transfer Type]-Dual AbutmentCompletion of wax-up. Metal framework. Final prosthesis build-up

Pagina 19 - Prosthetic Procedure 2

Fixture Level-SCA Abutment SimpleLine ll Surgical / Prosthesis Manual26Clinical ProcedureHealing AbutmentFixture Level Impression Pick-up TypeOpen Tra

Pagina 20 - Fixture Level

SimpleLine ll Surgical / Prosthesis Manual27Fixture Level-SCA AbutmentAssemble the SCA abutment. If deemed necessary, abutment milling is possible.Fab

Pagina 21

Fixture Level-Dual Milling AbutmentSimpleLine ll Surgical / Prosthesis Manual28Connect analogs with theset impression material.Soft tissue modeling. C

Pagina 22

SimpleLine ll Surgical / Prosthesis Manual29Fixture Level-Dual Milling Abutment[Single Unit]Assemble the dual milling abutment. Milled the abutment to

Pagina 23

SURGICAL MANUALSurgical Drill Sequence 04Fixture Installation 05Fixture Connection 06Surgical Kit Maintenance 08Warnings 09

Pagina 24

Fixture Level-Angled AbutmentSimpleLine ll Surgical / Prosthesis Manual30[Single Unit]Impression coping with analog connections.Soft tissue formation

Pagina 25

SimpleLine ll Surgical / Prosthesis Manual31Fixture Level-Angled Abutment[Single Unit]Create the master model. Assemble the angled abutment. Milled th

Pagina 26

Fixture Level-Direct-Casting AbutmentSimpleLine ll Surgical / Prosthesis Manual32[Single Unit]Impression coping with analog connections.Soft tissue fo

Pagina 27

SimpleLine ll Surgical / Prosthesis Manual33Fixture Level-Direct-Casting AbutmentAssemble the direct casting abutment. Completed customized abutment.

Pagina 28

SimpleLine ll Surgical / Prosthesis Manual34Prosthetic Procedure 3Impression Technique and Restoration SelectionScrew AbutmentScrew-Retained Restorati

Pagina 29

SimpleLine ll Surgical / Prosthesis Manual35Abutment Level-Screw Abutment[Multiple Units]Select and seat an appropriate screwabutment with delivery ho

Pagina 30

SimpleLine ll Surgical / Prosthesis ManualAbutment Level-Screw Abutment36Laboratory ProcedureLab Analog Connection Cylinder Connection Modification Cr

Pagina 31

SimpleLine ll Surgical / Prosthesis Manual37Abutment Level-Screw AbutmentGold framework. Use the reamer to remove the "Lip" inthe interior o

Pagina 32

Cementation Repair Method (SCRP)SimpleLine ll Surgical / Prosthesis Manual38[Screw & Cement Retained Prosthesis]In light of Implant Prosthesis:• S

Pagina 33

SimpleLine ll Surgical / Prosthesis Manual39Cementation Repair Method (SCRP)[Screw & Cement Retained Prosthesis]Remove the screw completely withsc

Pagina 34 - Prosthetic Procedure 3

SimpleLine ll Surgical / Prosthesis ManualSurgical Drill Sequence0481012 14 163.4 3.8 4.34.3 4.8Final drillTap drillFirstguidedrillSecondguide drill

Pagina 35

SimpleLine ll Surgical / Prosthesis Manual40Prosthetic Procedure 4Impression Technique and Restoration TypeOverdenture ProcedureMini Ball and Socket A

Pagina 36

SimpleLine ll Surgical / Prosthesis Manual41PositionerTake impression for the production ofthe individual tray.Connect the Positioner Abutment ontothe

Pagina 37

SimpleLine ll Surgical / Prosthesis Manual42PositionerCreate holes for the placement of the metal sockets.Apply the resin into the holes and waituntil

Pagina 38

SimpleLine ll Surgical / Prosthesis Manual43Ball AttachmentAffix the impression coping on the Ball Abutment.Take the final impression with the prepare

Pagina 39

SimpleLine ll Surgical / Prosthesis Manual44Case 2Create holes for the placement of the female sockets.Apply the resin into the holes and waituntil it

Pagina 40 - Prosthetic Procedure 4

SimpleLine ll Surgical / Prosthesis Manual45Remove the Healing Abutment.Connect implant keeper with the fixtureand tighten it with 25~30 N‧cm.Implant

Pagina 41 - Positioner

SimpleLine ll Surgical / Prosthesis ManualMagnetic Attachment46Create holes for the placement ofthe magnets.Examine for interference between theinner

Pagina 44

Fixture InstallationSimpleLine ll Surgical / Prosthesis Manual05Final drill Ø4.3Final drill Ø4.8Ø4.8Ø6.5Final drill Ø4.3Final drill Ø4.8Tap drillØ4.8Ø

Pagina 45 - Magnetic Attachment

SimpleLine ll Surgical / Prosthesis ManualFixture Connection06Caution_ When opening the fixture package,hold it upright to avoid falling out ofthe fix

Pagina 46

SimpleLine ll Surgical / Prosthesis Manual07Removal of the Fixture Mount Removal Mechanism of the Fixture MountRun the hand-piece in reverse mode.Fix

Pagina 47

SimpleLine ll Surgical / Prosthesis Manual08Surgical Kit MaintenanceSterilization and Instrument Care Procedures • Please follow legal regulations, as

Pagina 48

SimpleLine ll Surgical / Prosthesis Manual09WarningsWarningsDental implant surgery and restoration involve complex dental procedures. Appropriate and

Comentarios a estos manuales

Sin comentarios